Instructions for loading the Middelfart image derived from TM data acquired on 3rd June 2004

  1. Place the binary file into an appropriate directory. In ILWIS, use the Navigator to navigate to this directory. You will not see the name of the binary file, because it is not in a recognised ILWIS format.

  2. Import using General Raster. Once the correct file has been located, the General Raster page displays. Header size is zero, 3 bands, 1247 columns, Byte pixel structure, BSQ format and convert to ILWIS data format. Press Okay. In the directory will appear a three layered coloured grid. This is a maplist.

  3. Display the image. Double click on the maplist symbol and a panel will appear listing three layer images. Above these is a Television screen; click it and another panel will appear. Change Middelfart3 to the blue band and Middelfart1 to the red band and press Okay. The false colour image will appear.

  4. The watercourse in the centre of the image is Lillebaelt, between the island of Fyn to the east and Jutland to the west. The old bridge, containing both rail and roadways, is to the south and the new road bridge is to the north. The old bridge connects directly to Middelfart, the town on Fyn, between the bridges and the roads coming from them. On Jutland, at the northern part of the image, is the city of Fredericia, with its harbour area and the old defensive works still obvious. Between the City of Fredericia and its southern extension is a forest area, just as there are forest areas to the west and north of Middelfart on Fyn. The commercial and industrial areas of Middelfart and Fredericia are intense cyan colour, whilst residential areas contain some red. Most of the remainder of the area is given over to agriculture, with fields of various crops obvious on the image as shades of red and bare soil areas in cyan. The motorway crossing the Lillebaelt on the new bridge connects Copenhagen to the east, with Jutland to the west, Europe to the south and Norway to the north. To the west of the image this motorway divides into two, one route going north and the other going south.

  5. Create Training areas for the classification. Using the image window File Menu, Create a Sample Set. A small panel opens, containing our maplist. Give a name for the sample set, and create a domain by pressing the Create Domain button. A Create Domain Panel opens. Specify a Domain Name, set Type Class and enter a description. Press Okay. A new panel, for the Domain Editor appears. In this panel, click the Add Item button, a palette with a cross, give a name, code and a description, using the ones given in the table below. After each entry is made, that entry will appear in the panel.

    Class Name Code Description
    Water A All water areas
    Bare Surfaces B All bare surfaces including soil and hard standing
    Commercial C Commercial/Industrial areas
    Forest D Areas of predominantly forest cover
    Crop (Rape) H Fields of Rape
    Crop (WW) J Winter Wheat fields
    Crop(SB) K Spring Barley fields


  1. When this panel is complete with the seven entries, then edit the colours associated with each class by pressing the Open Representation button, showing an artists palette. The seven classes are depicted on the Representation Class Panel that appears. Use the slider bars to change the colour of the highlighted class and repeat for the other classes. Close this panel when complete, and the Domain Class panel. The domain name appears in the Create Sample Set panel. Click Okay on this panel.

  2. The Sample Set Editor will automatically start, With two windows; a Map Window showing the image and a Statistics Window showing sample set statistics, currently blank.

  3. Zoom in on an area containing a sample area for one class, then press the Normal button to stop the zoom. Select the pixels by moving the cursor to a corner of the selected training area, pressing the left mouse button and dragging it to cover the area. When the mouse button is released, the statistics for this window will appear in the Current Selection table of the Statistics Window, and the sample area will be cross hatched. If it is not cross hatched, zoom in again and repeat the process until it does appear this way. Within the cross-hatched area. Click the right mouse button to reveal the context sensitive menu and select edit. A small window will appear; select the appropriate class and exit. The statistics will be merged with those already in the top window for this class. Add further training areas for this class, and then repeat the process for each other class.

  4. To classify, close all of the windows, and from the Catalog, click the Sample Set symbol created with the right mouse button and select classify. The Classify Dialog Box appears. Select Minimum Distance or Maximum Likelihood Classifier as the classification method. Specify an output file name and initiate the classification. After a short period the classification will be displayed.


Download these instructions as pdf file.